Boiler Dry Firing Safety Stat GT171: This safety stat prevents the boiler from operating when the water level is too low, protecting it from damage caused by dry firing.
-
Tundish Superseded By XG207 (XG173): The tundish provides a visual indication of any discharge from safety valves or overflows, ensuring system safety and compliance.
-
Relay Base XB147 / Relay XB146: These components control the activation and deactivation of specific functions within the boiler, providing control over various operations.
-
2 Pole Contactor, 25Amp XB014: A switch used to control the power supply to specific components within the boiler, enhancing system control and safety.
-
Y Strainer XB314: Filters out debris and impurities from the water supply, protecting sensitive components like pumps and valves from damage and ensuring smooth operation.
-
Filling Loop XG004/5/6 (XG118): Used to fill and pressurize the boiler system, ensuring proper operation and preventing airlocks.
-
By-Pass Valve XG182: Regulates water flow within the boiler system, optimizing performance and preventing damage from excessive pressure.
-
Ballvalve FT207 / 90 Degree Angle Ballvalve XB398: Valves that control the flow of water within the boiler system, allowing for manual shut-off and control over water flow direction.
-
Pressure reducing valve XB391 / CA Backflow Prevention Valve XB390: These valves regulate water pressure and prevent backflow, ensuring safe and efficient operation of the boiler.
-
5 Amp Fuse XB382 / 25 Amp Fuse XB364 / AC30 Fuse Base XB363: Protects electrical components from overcurrents and short circuits, ensuring system safety.
-
Plastic F + E Tank XB343: The F + E (Feed and Expansion) tank maintains proper water levels in the boiler system, accommodating expansion and preventing overpressure.
-
Main Control PCB GT490: Controls the operation of various components within the boiler, ensuring proper functionality and performance.
-
Fan GT335 / Flame Sensing Electrode GT309 / Spark Electrode GT307: These components are essential for the ignition and combustion process within the boiler, ensuring efficient and safe operation.
-
Sampling Point Cap GT252: Protects the sampling point from contamination and damage, ensuring accurate testing and monitoring of boiler water quality.
-
Expansion Relief Valve GT195: Releases excess pressure from the expansion vessel, preventing damage due to overpressure.
-
Gas Valve GT185 / Gas Tap GT025: Controls the flow of gas to the burner, allowing for safe and efficient combustion.
-
Primary System Pressure Gauge GT179: Provides a visual indication of the boiler's pressure, allowing for easy monitoring and adjustment.
-
Displacement Tube Below GT168 / Displacement Tube Above GT167 / Displacement Ceramic Core GT166: These components are part of the displacement system, ensuring accurate measurement of boiler water levels.
-
Fan Gasket GT165: Seals the fan unit, preventing air leaks and ensuring efficient operation.
-
Burner Assembly GT163: Contains the burner components responsible for combustion within the boiler.
-
12 Litre Expansion Vessel GT162: Accommodates fluctuations in water volume due to heating, preventing damage to the system from excessive pressure.
-
22mm Angle Pump Valve GT135 / 22mm Straight Pump Valve GT133: Valves that control the flow of water through the pump, facilitating efficient circulation within the system.
-
Gas Plug In PCB GT102: Controls the operation of the gas valve and ignition system, ensuring safe and efficient combustion.
-
Grundfos 15/50 Pump GT089: A reliable pump responsible for circulating water within the boiler system.
-
Flow Regulator GT086: Regulates water flow, optimizing energy efficiency and preventing pressure fluctuations.
-
Overheat Thermostat GT064: Monitors boiler temperature and shuts down the system if temperatures exceed safe limits, preventing damage and ensuring safety.
-
Anti Vacuum Valve GT056: Prevents the formation of a vacuum within the boiler system, ensuring smooth water flow and preventing damage to components.
-
Honeywell Hydronic Valve GT047: Controls the flow of water within the boiler system, allowing for precise temperature control and efficient heating.
-
Plate Heat Exchanger GT017: Transfers heat between different water circuits within the boiler system, maximizing energy efficiency and hot water production.
-
Automatic Air Vent GT015: Automatically releases trapped air from the boiler system, ensuring optimal performance and preventing airlocks.